Industrial Calibration
1.0.0
|
Public Attributes | |
bool | converged |
Whether the underlying solver converged. If this is false, your calibration did not go well. If this is true, your calibration MAY have gone well. | |
double | initial_cost_per_obs |
The initial reprojection error (in pixels) per residual based on your input guesses. | |
double | final_cost_per_obs |
The final reprojection error (in pixels) per residual after optimization. Note that each circle has two residuals: a U and V error in the image. So a value of 1.2 means that each circle was described to within 1.2 pixels in X and 1.2 pixels in Y. | |
Eigen::Isometry3d | base_to_target |
The final location of the target. | |
double industrial_calibration::MultiCameraPnPResult::final_cost_per_obs |
A low value here is encouraging if you had a diversity of images. If you took few images, you can get a low score without getting a calibration that describes your workcell.